web templates free download

IOLVip Revolution Acrylic

The IOL-Vip Revolution Acrylic lenses work together to act like a telescope, gently magnifying the image entering the eye and diverting it to a healthier part of the retina. This section of healthier retina receives the image, taking over the role of the macula and can provide the AMD patient with significantly improved vision.
IOL-Vip Revolution Acrylic, is a capsular bag and sulcus mini telescope, whose innovative characteristics are the haptics of the negative IOL square edge that create a barrier against the posterior capsule opacity (PCO), the thickness prevents contact between the anterior capsule and the rear.
The acrylic material allows us to have a device handy and easy to implant through the standard injectors. The safety and biocompatibility of the material is ensured by a decade of experience done with the same material used for the intraocular lenses.
To improve the visual performance of patients with ARMD or very high myopia and reduce dramatically the PCO, with IOL-Vip Revolution Acrylic we proceeded to implement the new model with innovative dimensions and material compared to those currently available on the world market.

IOL-Vip HP

Suitable for capsular bag implantation, these lenses feature high haptics flexibility which makes insertion easy and ensures optimal centration.

Optical Disk

Material: Acrylic with UV filter

Diameter: 5.0

Hole: none

Loupes

Shape: four rings

Material: Acrylic

Angle: +/- 1°

Total IOL length: 11.0

Power: from 0.00 to -100.00

IOL-Vip HA

Suitable for sulcus implantation, these lenses feature high haptics flexibility which makes insertion easy and ensures optimal centration.

Optical Disk

Material: Acrylic with UV filter

Diameter: 5.0

Hole: none

Loupes

Shape: cupole

Material: Acrylic

Angle: +/-1°

Total IOL length: 13.0

Power: from 0.00 to +100.00

EXCLUSION CRITERIA

The same ones used for the cataract surgery
No benefit from the visual test simulator with prismatic effect
No visual advantage from the test with the simulator without prismatic effect
Lack of motivation

INCLUSION CRITERIA

The same ones used for the cataract surgery
Visual recovery from the test with the simulator with prismatic effect
Visual recovery from the test with the simulator without prismatic effect good motivation

DRUG THERAPY
The same as that used for cataract surgery

CONTROLS AND REHABILITATION THERAPY
The day after the intervention
8 days after surgery with prescription of rehabilitation therapy (software NeWinFlash)

In the case of rehabilitation therapy:
6 weeks after the start of the first round of rehabilitation therapy (software NeWinFlash)
6 weeks after the beginning of the second cycle of rehabilitation therapy (software NeWinFlash)

IOL-Vip Revolution Acrylic
Address

SUBVISION S.r.l. ¬ Via G. da Procida, 6 ¬ 20149 Milano ¬
Capitale sociale € 10.400 ¬
Registro Imprese di Milano Codice Fiscale e Partita IVA: 08426690155